By Wattproof Editorial Team. Last reviewed 5 October 2026. Figures and schemes change — verify with an MCS-certified installer before you commit.

The calculator estimates your solar output in five steps, and every number in them is one you can see. It works from your roof's usable area, the panels that fit, a national yield per kWp calibrated to PVGIS (the European Commission's solar tool), and which way the roof faces. This page sets out the method and the figures it uses, so you can check them and judge how far to trust the result.

This guide covers solar output only. How we calculate savings covers the whole estimate: the battery, heat pump, EV, hot water, tariffs, grants and limits.

  1. Measure the usable roof face. Take the area of the roof face you'd put panels on, clear of chimneys, skylights and dormers — or let a postcode lookup estimate it from aerial data.
  2. Keep 0.4 m clear of every edge. Installers leave space at the ridge, eaves and verges, so only the inner part of the roof holds panels. We subtract a 0.4 m margin on every side.
  3. Count the panels that fit. Divide the inner area by a modern panel's footprint (about 1.95 m² for a 440 W panel) and round down to whole panels.
  4. Apply the national yield. Multiply system size by the yield per kWp: about 950 kWh per kWp a year, the same national figure for every roof. You can edit it in the calculator. It does not change with where you live; the county pages show how PVGIS yields differ by area.
  5. Adjust for direction, slope and shading. Scale for which way the roof faces and how steep it is (south at 35° is the reference; east or west at a typical slope lose about 20%) and for any shading you've told us about.

The figures behind each step

StepWhat it uses
Panel sizeA 440 W panel of about 1.72 m by 1.13 m, which is about 1.95 m²
Edge clearance0.4 m on every side of the roof face
National yield950 kWh per kWp a year for a south-facing, unshaded roof
Direction, at a typical 35° slopeSouth 100%, south-east or south-west 94%, east or west 80%, north-east or north-west 63%, north 55%
Slope, facing southShallow (17.5°) 95%, typical (35°) 100%, steep (55°) 97%
Flat roofFrames at about 12.5°: 92% facing south, 83% east-west, so 88% on average; only 70% of the usable area is counted for panels (our assumption)
ShadingNone 100%, light 90%, heavy 75%
Ageing0.5% less output each year

A worked example

The calculator doesn't know the shape of your roof face, only its area, so it assumes the face is twice as wide as it is deep, which is our own assumption for a typical UK house. It isn't square. On typical roofs the result moves by at most one panel between a face 1.5 times and 3 times as wide as deep.

Take a south-facing face of 28 m², with yields from PVGIS. Here is the arithmetic, which you can follow with a calculator:

  1. Width and depth. Width × depth = 28, and width = 2 × depth. So depth = √(28 ÷ 2) = √14 = 3.74 m, and width = √(28 × 2) = √56 = 7.48 m. Check: 7.48 × 3.74 = 28.
  2. Keep 0.4 m clear of every edge. That takes 0.8 m off the width and 0.8 m off the depth: 7.48 − 0.8 = 6.68 m, and 3.74 − 0.8 = 2.94 m.
  3. Inner area. 6.68 × 2.94 = 19.6 m².
  4. Panels. 19.6 ÷ 1.95 = 10.07, rounded down to 10 panels.
  5. System size. 10 × 0.44 kWp = 4.4 kWp.

At the national yield, 4.4 kWp makes 4.4 × 950 = 4,180 kWh a year. If the roof faces south-west instead, at a typical slope, that is 4,180 × 0.94 = about 3,930 kWh. With light shading too, it is 3,930 × 0.9 = about 3,540 kWh.

Dividing the raw 28 m² by the panel size would suggest 14 panels, which is why the edge clearance step matters. Our guide to how many panels you need shows the difference.

How the county pages differ

The calculator uses the national figure of 950 kWh per kWp for every roof, and does not scale it by area. The county pages work differently: for the counties we've calculated, the yield runs from 787 kWh per kWp in Highland to 1,035 in Cornwall. We take the figure from PVGIS (the European Commission's Joint Research Centre; see its usage conditions) for one point in a reference town in each county, for a south-facing system at 35°, and scale every county so the middle of the first 15 sits on the 950. Each county's page shows the unscaled PVGIS figure, the scale factor and the result.

Yields: PVGIS v5.3 (European Commission, Joint Research Centre), scaled by us to the calculator's 950 kWh/kWp national reference. Radiation data: SARAH-3, copyright 2026 EUMETSAT (CM SAF), doi 10.5676/EUM_SAF_CM/SARAH/V003. Meteorological data: contains modified Copernicus Climate Change Service information 2026. Full credits and licence statements.

How direction and slope are worked out

The direction and slope factors come from the same PVGIS data as the county yields. We ran PVGIS for a grid of slopes (from flat to vertical) and compass directions at three places, Cornwall, Leicestershire and Highland, divided each result by that place's own south-facing 35° result, averaged the three, and made the grid symmetric east to west, because which of east or west does better differs from place to place with the weather. A south-facing roof at 35° is exactly 1.00, so the 950 kWh per kWp reference and every county figure are unchanged. For slopes and directions between the grid's points we interpolate.

Steeper east and west roofs lose more: PVGIS gives an east or west face about 82% of the reference at 17.5°, 80% at 35°, 77% at 45° and 72% at 55°, because a steep face points further from the sun. Individual places differ from these factors: by up to about 2.5 points anywhere on the grid, and by 2 or less at the slopes most roofs have, 10° to 60°. The data credits above apply to these figures too. Treat a factor as a good guide, not a measurement of your roof. Our orientation guide shows the figures for every slope and direction.

If you use the roof lookup, each ticked face gets the factor for its own direction and pitch. The faces are weighted by their share of the panels and the result is applied to the system size, so a roof with a south-east and a south-west face is worked out face by face, not as one direction.

A flat roof means panels on frames at about 12.5°, laid out either facing south or east-west. PVGIS gives 92% of the reference for south-facing frames and 83% for east-west, and the calculator uses the average, 88%. Frames need gaps so they don't shade each other, so the calculator counts panels on 70% of the usable area, then keeps 0.4 m clear at each edge as on a pitched roof. The 70% is our assumption, a blend of about 55% for south-facing rows and about 87% for east-west layouts. For a 28 m² roof that gives 6 panels (2.64 kWp) where a pitched roof holds 10. An installer's layout is the check.

What happens after the yield

The yearly output is split across the months using the mean of the PVGIS monthly profiles for Cornwall, Leicestershire and Highland, for a south-facing system at 35°. It runs from 2.8% of the year in December to 12.8% in May: January 3.3%, February 5.1%, March 8.6%, April 11.7%, May 12.8%, June 12.4%, July 12.4%, August 11.2%, September 9.3%, October 6.4%, November 4.0%, December 2.8%.

Yields: PVGIS v5.3 (European Commission, Joint Research Centre), scaled by us to the calculator's 950 kWh/kWp national reference. Radiation data: SARAH-3, copyright 2026 EUMETSAT (CM SAF), doi 10.5676/EUM_SAF_CM/SARAH/V003. Meteorological data: contains modified Copernicus Climate Change Service information 2026. Full credits and licence statements.

Each month's output is then divided into what you use in the house and what's left over, using the share of your electricity you use in daylight. The surplus goes to a battery first if you have one, then to any other use you've selected, and the rest is exported. A battery is filled from solar first, then topped up in the cheapest window of your tariff, and runs one cycle a day, because what limits it is the evening electricity the home still buys, not its power. Savings come from pricing each part at your rates. Over 25 years the price you pay to import electricity rises by the percentage you set (3% a year unless you change it), and the export rate is held at today's level: export payments are set by your supplier, so we don't assume they rise.

What the method doesn't do

  • It doesn't model the weather hour by hour. It uses a typical year.
  • It doesn't know your exact tilt unless you use the lookup. Manual entry uses three slopes (shallow, typical, steep), and for a typical pitched roof direction, shading and size matter more than a few degrees of tilt, as our orientation guide explains.
  • It relies on the area you give it. A lookup from your postcode or a tap on the map fills it in, but obstacles such as chimneys and roof windows need an installer's survey.
  • It doesn't replace a survey. Use it to decide whether solar is worth pursuing and to compare quotes.

Frequently asked questions

How accurate is the calculator's solar estimate?
It's a planning estimate, not a survey. It uses one national yield per kWp for every roof (you can edit it), factors for direction, slope and shading, and the roof area you give it. A site survey from an MCS-certified installer is the final check.
Does the calculator use my roof's pitch?
Yes. For a pitched roof you enter the direction and choose a slope: shallow, typical (our default, about 35°) or steep. If you use the roof lookup, each ticked face's own direction and pitch is used instead. Direction still matters more than slope: a typical slope is within a few points of the best for most roofs.
Can I change the numbers it uses?
Yes. You can enter your own roof area, system size and install cost, and the results show what each assumption is.